Audio Fix / setup help

RME Babyface Pro FS: capture a prepared output submix with known input replacement

RME Babyface Pro FS: capture a prepared output submix with known input replacement. Check prerequisites and the actual response before reporting an outcome.

Manufacturer-documented Reviewed 2026-11-09 · Revision 1

Follow these checks in Audio Fix →

When this guide applies

Deliberate TotalMix submix recording rather than physical-input capture.

Connection scope: USB audio. Symptom: Recording or direct monitoring is not working.

This is a documented check, not a diagnosis of your equipment. The model name does not confirm the selected input, mode, software or connected partner.

If your exact model or a required setting is unknown, use the “I don’t know” branch below. Do not apply a similarly named model’s instructions.

Checks and possible outcomes

Start at step-0. Follow the link that matches what you actually observe. Alternative branches are not a single sequence of actions.

step-0

Is the desired safe output submix already prepared?

Do not route an unknown mix or invent an external loop cable.

Look for: Confirm the actual prerequisite or observation. Unknown stops safely.

  • Manufacturer-documented RME Babyface Pro FS official user guide ↗PDF pages 67 — Hardware Output Settings Loopback sends the output submix to its corresponding recording channels instead of that physical input. Software input monitoring can create feedback.Exact model/generation named in this manual; external controls and documented host paths only. · Source checked 2026-11-09

step-1

Is it acceptable that the corresponding physical input is replaced in recording software?

Loopback substitutes that recording-channel feed. Stop if an active microphone capture depends on it.

Look for: Confirm the actual prerequisite or observation. Unknown stops safely.

  • Manufacturer-documented RME Babyface Pro FS official user guide ↗PDF pages 67 — Hardware Output Settings Loopback sends the output submix to its corresponding recording channels instead of that physical input. Software input monitoring can create feedback.Exact model/generation named in this manual; external controls and documented host paths only. · Source checked 2026-11-09

step-2

May the stopped track change routing with software monitoring disabled?

Monitoring the returned signal can cause loud feedback; preserve old assignment.

Look for: Confirm the actual prerequisite or observation. Unknown stops safely.

  • Manufacturer-documented RME Babyface Pro FS official user guide ↗PDF pages 67 — Hardware Output Settings Loopback sends the output submix to its corresponding recording channels instead of that physical input. Software input monitoring can create feedback.Exact model/generation named in this manual; external controls and documented host paths only. · Source checked 2026-11-09

step-3

Disable software monitoring on the receiving track

Do this before enabling the output loopback.

Look for: Perform only the stated operation, then confirm whether it could be completed.

  • Manufacturer-documented RME Babyface Pro FS official user guide ↗PDF pages 67 — Hardware Output Settings Loopback sends the output submix to its corresponding recording channels instead of that physical input. Software input monitoring can create feedback.Exact model/generation named in this manual; external controls and documented host paths only. · Source checked 2026-11-09

step-4

Enable Loopback in that Hardware Output Settings panel

Use only the intended output and its corresponding record channels.

Look for: Perform only the stated operation, then confirm whether it could be completed.

  • Manufacturer-documented RME Babyface Pro FS official user guide ↗PDF pages 67 — Hardware Output Settings Loopback sends the output submix to its corresponding recording channels instead of that physical input. Software input monitoring can create feedback.Exact model/generation named in this manual; external controls and documented host paths only. · Source checked 2026-11-09

step-5

Does the receiving track meter show the prepared submix without feedback?

Keep monitoring disabled; turn Loopback off deliberately before returning to physical-input capture.

Look for: Confirm the actual prerequisite or observation. Unknown stops safely.

  • Manufacturer-documented RME Babyface Pro FS official user guide ↗PDF pages 67 — Hardware Output Settings Loopback sends the output submix to its corresponding recording channels instead of that physical input. Software input monitoring can create feedback.Exact model/generation named in this manual; external controls and documented host paths only. · Source checked 2026-11-09

Possible result

Checks completed — report what happened

Completion is not an automatic solved result. Report solved, partly helped, did not help or could not follow based on your actual observation. No Audio Review physical test is claimed.

steps completed

Reaching this result does not mean the issue is solved. Only your own feedback can report improvement.

    Possible result

    Keep these observations for official support

    A required prerequisite or response was not confirmed. Stop this sequence and use the exact model and partner documentation. Do not escalate to a factory reset, firmware installation, internal repair or unsafe wiring change.

    next support

    Reaching this result does not mean the issue is solved. Only your own feedback can report improvement.

      Possible result

      A required fact is unknown

      Confirm the exact model, connection, partner capability and current control state before continuing. Do not guess settings or operate an updating product.

      insufficient data

      Reaching this result does not mean the issue is solved. Only your own feedback can report improvement.

        All Audio Fix guides → · TV & Audio Finder →